eWave + stimulator
portable EP-EMG / NCV recording device
An electromyelogram (EMG) is a test that is used to record the electrical activity of muscles. When muscles are active, they produce an electrical current. Typically, an EMG is given at the same time as a nerve conduction study. The most common type of nerve conduction study is known as a Nerve Conduction Velocity test. These tests are used to diagnose nerve injuries and muscle damage. Very often they will be given to individuals who have suffered low back injuries or neck injuries to diagnose nerve damage which may be occurring into the person's upper or lower extremities (arms or legs). The NCV will measure how quickly and completely a person's arm or leg nerve transfers "information", or how quickly and completely they respond. If nerve damage has occurred very often the response will be delayed or incomplete.
Light weight and Low power
3 channel EMG/ENG recording
Profesional mixer for desgen stumulus patern
ePulse have a Higth votlage stimulator(350V)
ePulse have a powerfull software for design protocol
epulse have 4 channels pulse generator
محصول
|
eWave8D/16D |
eWave32-64-128D |
eWave2S |
eWave4S |
electromodule |
eLab2/4/8/16/32 |
eClamp |
تعداد کانال آمپلی فایر
|
8/16 |
32/64/128 |
2+1 |
3+1 |
1 |
8/16/32 |
1 |
نوع آمپلی فایر
|
تفاضلی/مستقیم |
تفاضلی/مستقیم |
تفاضلی/مستقیم |
تفاضلی/مستقیم |
تفاضلی/مستقیم |
تفاضلی/مستقیم |
مستقیم |
دقت مبدل آنالوگ به دیجیتال
|
24 bit |
24 bit |
24 bit |
24 bit |
24 bit |
24 bit |
24 bit |
نرخ نمونه برداری هرکانال
|
1 ks/s |
500s/s |
10ks/s |
5ks/s |
50ks/s |
30-50ks/s |
100ks/s |
پردازش گر
|
32bit/128MHZ |
32bit/153MHZ |
32bit/128MHZ |
32bit/72MHZ |
FPGA |
32bit/168MHZ |
32bit/168 MHZ |
نوع اتصال
|
USB2 Bluetooth wireless |
WI-FI/USB2 |
USB2 |
USB2 Bluetooth wireless |
USB2 |
USB2 |
USB2 |
محرک جریان
|
ندارد |
ندارد |
دارد((5mA,150v،1µA range |
دارد(100 mA,350v) |
دارد 4/20mA,150V)) |
دارد ( 4/20mA,150V) |
دارد ( 4/20mA,150v) |
بهره
|
6 |
6 |
6 |
6 |
20 |
50 |
1 |
ورودی دیجیتال
|
2 |
2 |
2 |
2 |
2 |
2 |
2 |
خروجی دیجیتال
|
2 |
2 |
2 |
2 |
2 |
2 |
2 |
ورودی آنالوگ
|
1 |
0 |
0 |
0 |
0 |
0 |
0 |
خروجی آنالوگ
|
1 |
0 |
0 |
0 |
0 |
0 |
0 |
ابعاد(طول/عرض/ارتفاع)mm
|
120x28x60 |
155x33x95 |
120x28x60 |
155x33x95 |
366x116x350 |
120x28x60 |
120x28x60 |
مقاومت ورودی
|
109 Ω |
109 Ω |
109 Ω |
109 Ω |
1012 Ω |
1012 Ω |
1012 Ω |
کارکردباتری قابل شارژ
|
12 Hours |
12Hours |
12 Hours |
12 Hours |
5V adaptor–no Bat |
5V USB input –no Bat |
5V USB input –no Bat |
پهنای باند فیلتر |
DC -500Hz |
DC -250Hz |
DC -5KHz |
DC -2KHz |
0.5Hz -3KHz |
0.5Hz -10KHz |
DC -10KHz |
کاربرددرثبت الکتروانسفالوگرام/ الکتروکورتیکوگرام/ الکتروکاردیوگرافی/ الکترومیوگرافی الکترواکولوگرافی |
دارد |
دارد |
دارد |
دارد |
دارد |
دارد |
ندارد |
کاربرددرثبت پتانسیل وابسته به رخداد(ERP) |
دارد(8/16ch) |
دارد(32/64/128) |
ندارد |
ندارد |
ندارد |
دارد |
ندارد |
سنسور مقاومت پوست،دما،فشارخون حجمی، EEG,EMG,ECG |
دارد |
دارد |
ندارد |
ندارد |
ندارد |
ندارد |
ندارد |
ثبت پتانسیل میدانی(LFP) |
ندارد |
ندارد |
دارد |
دارد |
دارد |
دارد |
ندارد |
ثبت تک واحدی(SUR)
|
ندارد |
ندارد |
ندارد |
ندارد |
دارد |
دارد |
ندارد |
ثبت داخل سلولی Patch Clamp (Voltage /Current |
ندارد |
ندارد |
ندارد |
ندارد |
ندارد |
ندارد |
دارد |
ثبت سرعت هدایت عصبی(NCV) |
ندارد |
ندارد |
دارد |
دارد |
دارد |
دارد |
ندارد |
کیندلینگ
|
ندارد |
ندارد |
دارد |
دارد |
دارد |
دارد |
ندارد |
پتانسیل برانگیخته بینایی
|
ندارد |
ندارد |
دارد |
دارد |
ندارد |
دارد |
ندارد |
دسته بندی اسپایک ها
|
ندارد |
ندارد |
ندارد |
ندارد |
Offline |
Offline/Online |
ندارد |
Animal electrophysiology system
Brain and Spinal cord / Invio and invitro extracellular recording(LFP,Single unit, ECog) intracellular and Patch Clamp recording EXG recording animal (EEG,EMG,ECG,EOG,T,GSR,BVP) Amplifiers, Electrical & Mechanical Stimulatars, Data acquisition, Window discriminators,Spike Sorter, Digital Microdrive, spike sorter
|
|
eProbe All you need to analysis neuro-electrophysiology signals |
![]() |
| ![]() |
Single-unit signals (spike) analysis
| |
![]() | PSTH Analysis
- Show sorted action potential in window discriminator
- Show 8 channel PSTH - Audio monitoring of raw signal and spikes - Measurement of delayed and frequency response, max, min, average, standard deviation and neuronal responses - Analysis for spinal cord neurons - Saving data analysis as a binary or excel file/ image/ analysis template |
Spike count
Calculating of spike number | Saving data analysis as binary or excel file/ image/ analysis template | | ![]() | ||
| |||||
![]() |
|
![]() |
eProbe a potent software for neuro-electrophysiology data analysis!
Potent software for electrophysiological data analysis.
Data extraction from EEG, field potential and single-unit signals (PSTH analysis and offline sorting) and statistical analysis of acquired data.
PSTH analysis and real time demonstration of recorded signals in single-unit data analysis mode with offline sorting and analysis capabilities.
Making data banks from results in excel or word files format.
Online demonstration of raw signal.
Offline PSTH analysis output includes average firing rate of neuron, standard deviation of firing, latency time of response, minimum and maximum response and spike count of different types of nerve fibers.
Special modes for analyzing Uni-trial and multi-trial experiments.
Analysis Field potential, volley potential, EPSP and PS signals in single-pulse or paired-pulse recording mode.
EPSP analysis including baseline resetting, measuring slope, amplitude, area under curve, latency time and minimum and maximum response.
EEG analysis including spike count, average of spikes amplitude, phase and power spectrum.
Graphical output for using in scientific manuscripts.
User friendly installation and application.
Complete manual for installation, application and analysis.
Some publications dealing with eProbe
Effects of apomorphine and β-carbolines on firing rate of neurons in the ventral pallidum in the rats; Behavioural Brain Research, Volume 227, Issue 1, 1 February 2012, Pages 109-115 |
Formalin-Induced Differential Activation of Nucleus Cuneiformis Neurons in the Rat: An Electrophysiological Study; The Journal of Pain, Volume 11, Issue 1, January 2010, Pages 32-43 |
Single whisker experience started on postnatal days 0, 5 or 8 changes temporal characteristics of response integration in layers IV and V of rat barrel cortex neurons; Brain Research Bulletin, Volume 74, Issues 1–3, 14 September 2007, Pages 29-36 |
Dorsal raphe nucleus stimulation modulates the response of layers IV and V barrel cortical neurons in rat; Brain Research Bulletin, Volume 68, Issue 6, 15 February 2006, Pages 430-435 |
Electrical stimulation of locus coeruleus strengthens the surround inhibition in layer V barrel cortex in rat; Neuroscience Letters, Volume 401, Issue 3, 3 July 2006, Pages 280-284 |
eWave + stimulator
portable EP-EMG / NCV recording device
An electromyelogram (EMG) is a test that is used to record the electrical activity of muscles. When muscles are active, they produce an electrical current. Typically, an EMG is given at the same time as a nerve conduction study. The most common type of nerve conduction study is known as a Nerve Conduction Velocity test. These tests are used to diagnose nerve injuries and muscle damage. Very often they will be given to individuals who have suffered low back injuries or neck injuries to diagnose nerve damage which may be occurring into the person's upper or lower extremities (arms or legs). The NCV will measure how quickly and completely a person's arm or leg nerve transfers "information", or how quickly and completely they respond. If nerve damage has occurred very often the response will be delayed or incomplete.
Light weight and Low power
3 channel EMG/ENG recording
Profesional mixer for desgen stumulus patern
ePulse have a Higth votlage stimulator(350V)
ePulse have a powerfull software for design protocol
epulse have 4 channels pulse generator
محصول
|
eWave8D/16D |
eWave32-64-128D |
eWave2S |
eWave4S |
electromodule |
eLab2/4/8/16/32 |
eClamp |
تعداد کانال آمپلی فایر
|
8/16 |
32/64/128 |
2+1 |
3+1 |
1 |
8/16/32 |
1 |
نوع آمپلی فایر
|
تفاضلی/مستقیم |
تفاضلی/مستقیم |
تفاضلی/مستقیم |
تفاضلی/مستقیم |
تفاضلی/مستقیم |
تفاضلی/مستقیم |
مستقیم |
دقت مبدل آنالوگ به دیجیتال
|
24 bit |
24 bit |
24 bit |
24 bit |
24 bit |
24 bit |
24 bit |
نرخ نمونه برداری هرکانال
|
1 ks/s |
500s/s |
10ks/s |
5ks/s |
50ks/s |
30-50ks/s |
100ks/s |
پردازش گر
|
32bit/128MHZ |
32bit/153MHZ |
32bit/128MHZ |
32bit/72MHZ |
FPGA |
32bit/168MHZ |
32bit/168 MHZ |
نوع اتصال
|
USB2 Bluetooth wireless |
WI-FI/USB2 |
USB2 |
USB2 Bluetooth wireless |
USB2 |
USB2 |
USB2 |
محرک جریان
|
ندارد |
ندارد |
دارد((5mA,150v،1µA range |
دارد(100 mA,350v) |
دارد 4/20mA,150V)) |
دارد ( 4/20mA,150V) |
دارد ( 4/20mA,150v) |
بهره
|
6 |
6 |
6 |
6 |
20 |
50 |
1 |
ورودی دیجیتال
|
2 |
2 |
2 |
2 |
2 |
2 |
2 |
خروجی دیجیتال
|
2 |
2 |
2 |
2 |
2 |
2 |
2 |
ورودی آنالوگ
|
1 |
0 |
0 |
0 |
0 |
0 |
0 |
خروجی آنالوگ
|
1 |
0 |
0 |
0 |
0 |
0 |
0 |
ابعاد(طول/عرض/ارتفاع)mm
|
120x28x60 |
155x33x95 |
120x28x60 |
155x33x95 |
366x116x350 |
120x28x60 |
120x28x60 |
مقاومت ورودی
|
109 Ω |
109 Ω |
109 Ω |
109 Ω |
1012 Ω |
1012 Ω |
1012 Ω |
کارکردباتری قابل شارژ
|
12 Hours |
12Hours |
12 Hours |
12 Hours |
5V adaptor–no Bat |
5V USB input –no Bat |
5V USB input –no Bat |
پهنای باند فیلتر |
DC -500Hz |
DC -250Hz |
DC -5KHz |
DC -2KHz |
0.5Hz -3KHz |
0.5Hz -10KHz |
DC -10KHz |
کاربرددرثبت الکتروانسفالوگرام/ الکتروکورتیکوگرام/ الکتروکاردیوگرافی/ الکترومیوگرافی الکترواکولوگرافی |
دارد |
دارد |
دارد |
دارد |
دارد |
دارد |
ندارد |
کاربرددرثبت پتانسیل وابسته به رخداد(ERP) |
دارد(8/16ch) |
دارد(32/64/128) |
ندارد |
ندارد |
ندارد |
دارد |
ندارد |
سنسور مقاومت پوست،دما،فشارخون حجمی، EEG,EMG,ECG |
دارد |
دارد |
ندارد |
ندارد |
ندارد |
ندارد |
ندارد |
ثبت پتانسیل میدانی(LFP) |
ندارد |
ندارد |
دارد |
دارد |
دارد |
دارد |
ندارد |
ثبت تک واحدی(SUR)
|
ندارد |
ندارد |
ندارد |
ندارد |
دارد |
دارد |
ندارد |
ثبت داخل سلولی Patch Clamp (Voltage /Current |
ندارد |
ندارد |
ندارد |
ندارد |
ندارد |
ندارد |
دارد |
ثبت سرعت هدایت عصبی(NCV) |
ندارد |
ندارد |
دارد |
دارد |
دارد |
دارد |
ندارد |
کیندلینگ
|
ندارد |
ندارد |
دارد |
دارد |
دارد |
دارد |
ندارد |
پتانسیل برانگیخته بینایی
|
ندارد |
ندارد |
دارد |
دارد |
ندارد |
دارد |
ندارد |
دسته بندی اسپایک ها
|
ندارد |
ندارد |
ندارد |
ندارد |
Offline |
Offline/Online |
ندارد |
Animal electrophysiology system
Brain and Spinal cord / Invio and invitro extracellular recording(LFP,Single unit, ECog) intracellular and Patch Clamp recording EXG recording animal (EEG,EMG,ECG,EOG,T,GSR,BVP) Amplifiers, Electrical & Mechanical Stimulatars, Data acquisition, Window discriminators,Spike Sorter, Digital Microdrive, spike sorter
|
|
eProbe All you need to analysis neuro-electrophysiology signals |
![]() |
| ![]() |
Single-unit signals (spike) analysis
| |
![]() | PSTH Analysis
- Show sorted action potential in window discriminator
- Show 8 channel PSTH - Audio monitoring of raw signal and spikes - Measurement of delayed and frequency response, max, min, average, standard deviation and neuronal responses - Analysis for spinal cord neurons - Saving data analysis as a binary or excel file/ image/ analysis template |
Spike count
Calculating of spike number | Saving data analysis as binary or excel file/ image/ analysis template | | ![]() | ||
| |||||
![]() |
|
![]() |
eProbe a potent software for neuro-electrophysiology data analysis!
Potent software for electrophysiological data analysis.
Data extraction from EEG, field potential and single-unit signals (PSTH analysis and offline sorting) and statistical analysis of acquired data.
PSTH analysis and real time demonstration of recorded signals in single-unit data analysis mode with offline sorting and analysis capabilities.
Making data banks from results in excel or word files format.
Online demonstration of raw signal.
Offline PSTH analysis output includes average firing rate of neuron, standard deviation of firing, latency time of response, minimum and maximum response and spike count of different types of nerve fibers.
Special modes for analyzing Uni-trial and multi-trial experiments.
Analysis Field potential, volley potential, EPSP and PS signals in single-pulse or paired-pulse recording mode.
EPSP analysis including baseline resetting, measuring slope, amplitude, area under curve, latency time and minimum and maximum response.
EEG analysis including spike count, average of spikes amplitude, phase and power spectrum.
Graphical output for using in scientific manuscripts.
User friendly installation and application.
Complete manual for installation, application and analysis.
Some publications dealing with eProbe
Effects of apomorphine and β-carbolines on firing rate of neurons in the ventral pallidum in the rats; Behavioural Brain Research, Volume 227, Issue 1, 1 February 2012, Pages 109-115 |
Formalin-Induced Differential Activation of Nucleus Cuneiformis Neurons in the Rat: An Electrophysiological Study; The Journal of Pain, Volume 11, Issue 1, January 2010, Pages 32-43 |
Single whisker experience started on postnatal days 0, 5 or 8 changes temporal characteristics of response integration in layers IV and V of rat barrel cortex neurons; Brain Research Bulletin, Volume 74, Issues 1–3, 14 September 2007, Pages 29-36 |
Dorsal raphe nucleus stimulation modulates the response of layers IV and V barrel cortical neurons in rat; Brain Research Bulletin, Volume 68, Issue 6, 15 February 2006, Pages 430-435 |
Electrical stimulation of locus coeruleus strengthens the surround inhibition in layer V barrel cortex in rat; Neuroscience Letters, Volume 401, Issue 3, 3 July 2006, Pages 280-284 |