eWave4s( دستگاه ثبت فیلد- ثبت NCV)

  • نام فروشگاه:  پرتو دانش آسمان
  • توضیحات محصول:
  • قیمت: 350,000,000 ریال
  • قیمت به حروف:     ( سیصد و پنجاه میلیون ریال )
  •     کالا یا خدمت مورد نظر در حال حاضر موجود نیست.
  • bag
  • افزودن کالا به سبد خرید
دربارهeWave4s

eWave + stimulator

portable EP-EMG / NCV recording device

 break

ePulse NCV/EMG-EP

An electromyelogram (EMG) is a test that is used to record the electrical activity of muscles. When muscles are active, they produce an electrical current. Typically, an EMG is given at the same time as a nerve conduction study. The most common type of nerve conduction study is known as a Nerve Conduction Velocity test. These tests are used to diagnose nerve injuries and muscle damage. Very often they will be given to individuals who have suffered low back injuries or neck injuries to diagnose nerve damage which may be occurring into the person's upper or lower extremities (arms or legs). The NCV will measure how quickly and completely a person's arm or leg nerve transfers "information", or how quickly and completely they respond. If nerve damage has occurred very often the response will be delayed or incomplete.

ep-p4-mini

  Light weight and Low power

3 channel  EMG/ENG recording

Profesional mixer for desgen stumulus patern

ePulse have a Higth votlage stimulator(350V)

ePulse have a powerfull software for design protocol

epulse have 4 channels pulse generator

ep-p4-mini

مقایسه محصولات

 

محصول

 

 

eWave8D/16D

 

eWave32-64-128D

 

eWave2S

 

eWave4S

 

electromodule

 

eLab2/4/8/16/32

 

eClamp

 

تعداد کانال آمپلی فایر

 

8/16

32/64/128

2+1

3+1

1

8/16/32

1

 

نوع آمپلی فایر

 

تفاضلی/مستقیم

تفاضلی/مستقیم

تفاضلی/مستقیم

تفاضلی/مستقیم

تفاضلی/مستقیم

تفاضلی/مستقیم

مستقیم

 

دقت مبدل آنالوگ به دیجیتال

 

24 bit

24 bit

24 bit

24 bit

24 bit

24 bit

24 bit

 

نرخ نمونه برداری هرکانال

 

1 ks/s

500s/s

10ks/s

5ks/s

50ks/s

30-50ks/s

100ks/s

 

پردازش گر

 

32bit/128MHZ

32bit/153MHZ

32bit/128MHZ

32bit/72MHZ

FPGA

32bit/168MHZ

32bit/168

MHZ

 

نوع اتصال

 

USB2

Bluetooth wireless

WI-FI/USB2

USB2

USB2

Bluetooth wireless

USB2

USB2

USB2

 

محرک جریان

 

ندارد

ندارد

دارد((5mA,150v،1µA  range

دارد(100 mA,350v)

دارد

4/20mA,150V))

دارد

( 4/20mA,150V)

دارد

( 4/20mA,150v)

 

بهره

 

6

6

6

6

20

50

1

 

ورودی دیجیتال

 

2

2

2

2

2

2

2

 

خروجی دیجیتال

 

2

2

2

2

2

2

2

 

ورودی آنالوگ

 

1

0

0

0

0

0

0

 

خروجی آنالوگ

 

1

0

0

0

0

0

0

 

ابعاد(طول/عرض/ارتفاع)mm

 

120x28x60

155x33x95

120x28x60

155x33x95

366x116x350

120x28x60

120x28x60

       

        مقاومت ورودی

 

10Ω

10Ω

10Ω

10Ω

1012 Ω

1012 Ω

1012 Ω 

 

کارکردباتری قابل شارژ

 

12 Hours

12Hours

12 Hours

12 Hours

5V adaptor–no Bat

5V  USB input –no Bat

5V  USB input –no Bat

 

پهنای باند فیلتر

DC -500Hz

DC -250Hz

DC -5KHz

DC -2KHz

0.5Hz -3KHz

0.5Hz -10KHz

DC -10KHz

کاربرددرثبت الکتروانسفالوگرام/

الکتروکورتیکوگرام/

الکتروکاردیوگرافی/

الکترومیوگرافی

الکترواکولوگرافی

دارد

دارد

دارد

دارد

دارد

دارد

ندارد

کاربرددرثبت پتانسیل

وابسته به رخداد(ERP)

دارد(8/16ch)

دارد(32/64/128)

ندارد

ندارد

ندارد

دارد

ندارد

سنسور مقاومت پوست،دما،فشارخون حجمی،

EEG,EMG,ECG

دارد

دارد

ندارد

ندارد

ندارد

ندارد

ندارد

 

ثبت پتانسیل میدانی(LFP)

ندارد

ندارد

دارد

دارد

دارد

دارد

ندارد

 

ثبت تک واحدی(SUR)

 

ندارد

ندارد

ندارد

ندارد

دارد

دارد

ندارد

ثبت داخل سلولی

Patch Clamp (Voltage /Current

ندارد

ندارد

ندارد

ندارد

ندارد

ندارد

دارد

 

 ثبت سرعت هدایت عصبی(NCV)

ندارد

ندارد

دارد

دارد

دارد

دارد

ندارد

 

کیندلینگ

 

ندارد

ندارد

دارد

دارد

دارد

دارد

ندارد

 

پتانسیل برانگیخته بینایی

 

ندارد

ندارد

دارد

دارد

ندارد

دارد

ندارد

 

دسته بندی اسپایک ها

 

ندارد

ندارد

ندارد

ندارد

Offline

Offline/Online

ندارد

دیگرمحصولات

Animal electrophysiology system

 

Brain and Spinal cord / Invio and invitro

extracellular recording(LFP,Single unit, ECog)

intracellular and Patch Clamp recording 

EXG recording animal (EEG,EMG,ECG,EOG,T,GSR,BVP)

Amplifiers, Electrical & Mechanical Stimulatars, Data acquisition, Window discriminators,Spike Sorter, Digital Microdrive, spike sorter

 

  

 

Human electrophysiology

 

eWave2,8: Biofeedback & Neurofeedback System

 

eWave 128, 64, 32 & 16Wireless ERP, QEEG and EXG(EEG,EOG,EMG,ECG) 

 

eWave4S : EP-EMG/NCV recording

 

eProbe: an effective software for neurofeedback data Recording and analysis!

 

نرم افزار

eProbe All you need to analysis neuro-electrophysiology signals

All

 Field potential signal analysis

 

Import data from previous version (NeuroTrace)
Display signal on high performance offline scope
Ability to optimize scope scales, both vertical and horizontal
Signal visualization in single and multi-trial mode
Signal inverting
Trial trimming (Disable bad trial) 
Hyper polarization, EPSP, PS, VP. 
One and multi trial Analysis 
Four LFP analysis mode (Standard, EPSP, Volley Potential (VP) + EPSP, PS mode)
Automatic measurement of defined variables (max, min, slope of the all analysis  line, 90%-10% of the line slope, area under the curve, start time, delay and response end) 
Saving data analysis as a binary or excel file/ image/ analysis template
 
Potentalize EPSP

 

Single-unit signals (spike) analysis

 

PSTH hand             

               PSTH Analysis

 

 

                - Show sorted action potential in window discriminator

  

                - Show 8 channel  PSTH

                - Audio monitoring of raw signal and spikes  

                - Measurement of delayed and frequency response, max, min, average,

                  standard deviation and neuronal responses

                - Analysis for spinal cord neurons

                - Saving data analysis as a binary or excel file/ image/ analysis template

                

EEG signal analysis


 

 

Spike count

 

Calculating of spike number
Saving data analysis as binary or excel file/ image/ analysis template

SpikeCount

 

 break 

 

FFT         

Frequency analysis

 

Caclculate power and phase frequency range 0-100 HZ, between two custome time
Drowing power and phase frequency graph
Saving data analysis as binary or excel file/ image

break

Statistical analysis

 

PSTH statis

eProbe a potent software for neuro-electrophysiology data analysis!

 

 

PSTH hand 

 

 

Potent software for electrophysiological data analysis.

Data extraction from EEG, field potential and single-unit signals (PSTH analysis and offline sorting) and statistical analysis of acquired data.

PSTH analysis and real time demonstration of recorded signals in single-unit data analysis mode with offline sorting and analysis capabilities.

Making data banks from results in excel or word files format.

Online demonstration of raw signal.

Offline PSTH analysis output includes average firing rate of neuron, standard deviation of firing, latency time of response, minimum and                           maximum response and spike count of different types of nerve fibers.

Special modes for analyzing Uni-trial and multi-trial experiments.

Analysis Field potential, volley potential, EPSP and PS signals in single-pulse or paired-pulse recording mode.

EPSP analysis including baseline resetting, measuring slope, amplitude, area under curve, latency time and minimum and maximum response.

EEG analysis including spike count, average of spikes amplitude, phase and power spectrum.

Graphical output for using in scientific manuscripts.

User friendly installation and application. 

Complete manual for installation, application and analysis.

 

break

Some publications dealing with eProbe

Effects of apomorphine and β-carbolines on firing rate of neurons in the ventral pallidum in the rats; 
Behavioural Brain Research, Volume 227, Issue 1, 1 February 2012, Pages 109-115
Formalin-Induced Differential Activation of Nucleus Cuneiformis Neurons in the Rat: An Electrophysiological Study; The Journal of Pain, Volume 11, Issue 1, January 2010, Pages 32-43
Single whisker experience started on postnatal days 0, 5 or 8 changes temporal characteristics of response integration in layers IV and V of rat barrel cortex neurons;
Brain Research Bulletin, Volume 74, Issues 1–3, 14 September 2007, Pages 29-36
Dorsal raphe nucleus stimulation modulates the response of layers IV and V barrel cortical neurons in rat; Brain Research Bulletin, Volume 68, Issue 6, 15 February 2006, Pages 430-435
Electrical stimulation of locus coeruleus strengthens the surround inhibition in layer V barrel cortex in rat; Neuroscience Letters, Volume 401, Issue 3, 3 July 2006, Pages 280-284

eWave + stimulator

portable EP-EMG / NCV recording device

 break

ePulse NCV/EMG-EP

An electromyelogram (EMG) is a test that is used to record the electrical activity of muscles. When muscles are active, they produce an electrical current. Typically, an EMG is given at the same time as a nerve conduction study. The most common type of nerve conduction study is known as a Nerve Conduction Velocity test. These tests are used to diagnose nerve injuries and muscle damage. Very often they will be given to individuals who have suffered low back injuries or neck injuries to diagnose nerve damage which may be occurring into the person's upper or lower extremities (arms or legs). The NCV will measure how quickly and completely a person's arm or leg nerve transfers "information", or how quickly and completely they respond. If nerve damage has occurred very often the response will be delayed or incomplete.

ep-p4-mini

  Light weight and Low power

3 channel  EMG/ENG recording

Profesional mixer for desgen stumulus patern

ePulse have a Higth votlage stimulator(350V)

ePulse have a powerfull software for design protocol

epulse have 4 channels pulse generator

ep-p4-mini

 

محصول

 

 

eWave8D/16D

 

eWave32-64-128D

 

eWave2S

 

eWave4S

 

electromodule

 

eLab2/4/8/16/32

 

eClamp

 

تعداد کانال آمپلی فایر

 

8/16

32/64/128

2+1

3+1

1

8/16/32

1

 

نوع آمپلی فایر

 

تفاضلی/مستقیم

تفاضلی/مستقیم

تفاضلی/مستقیم

تفاضلی/مستقیم

تفاضلی/مستقیم

تفاضلی/مستقیم

مستقیم

 

دقت مبدل آنالوگ به دیجیتال

 

24 bit

24 bit

24 bit

24 bit

24 bit

24 bit

24 bit

 

نرخ نمونه برداری هرکانال

 

1 ks/s

500s/s

10ks/s

5ks/s

50ks/s

30-50ks/s

100ks/s

 

پردازش گر

 

32bit/128MHZ

32bit/153MHZ

32bit/128MHZ

32bit/72MHZ

FPGA

32bit/168MHZ

32bit/168

MHZ

 

نوع اتصال

 

USB2

Bluetooth wireless

WI-FI/USB2

USB2

USB2

Bluetooth wireless

USB2

USB2

USB2

 

محرک جریان

 

ندارد

ندارد

دارد((5mA,150v،1µA  range

دارد(100 mA,350v)

دارد

4/20mA,150V))

دارد

( 4/20mA,150V)

دارد

( 4/20mA,150v)

 

بهره

 

6

6

6

6

20

50

1

 

ورودی دیجیتال

 

2

2

2

2

2

2

2

 

خروجی دیجیتال

 

2

2

2

2

2

2

2

 

ورودی آنالوگ

 

1

0

0

0

0

0

0

 

خروجی آنالوگ

 

1

0

0

0

0

0

0

 

ابعاد(طول/عرض/ارتفاع)mm

 

120x28x60

155x33x95

120x28x60

155x33x95

366x116x350

120x28x60

120x28x60

       

        مقاومت ورودی

 

10Ω

10Ω

10Ω

10Ω

1012 Ω

1012 Ω

1012 Ω 

 

کارکردباتری قابل شارژ

 

12 Hours

12Hours

12 Hours

12 Hours

5V adaptor–no Bat

5V  USB input –no Bat

5V  USB input –no Bat

 

پهنای باند فیلتر

DC -500Hz

DC -250Hz

DC -5KHz

DC -2KHz

0.5Hz -3KHz

0.5Hz -10KHz

DC -10KHz

کاربرددرثبت الکتروانسفالوگرام/

الکتروکورتیکوگرام/

الکتروکاردیوگرافی/

الکترومیوگرافی

الکترواکولوگرافی

دارد

دارد

دارد

دارد

دارد

دارد

ندارد

کاربرددرثبت پتانسیل

وابسته به رخداد(ERP)

دارد(8/16ch)

دارد(32/64/128)

ندارد

ندارد

ندارد

دارد

ندارد

سنسور مقاومت پوست،دما،فشارخون حجمی،

EEG,EMG,ECG

دارد

دارد

ندارد

ندارد

ندارد

ندارد

ندارد

 

ثبت پتانسیل میدانی(LFP)

ندارد

ندارد

دارد

دارد

دارد

دارد

ندارد

 

ثبت تک واحدی(SUR)

 

ندارد

ندارد

ندارد

ندارد

دارد

دارد

ندارد

ثبت داخل سلولی

Patch Clamp (Voltage /Current

ندارد

ندارد

ندارد

ندارد

ندارد

ندارد

دارد

 

 ثبت سرعت هدایت عصبی(NCV)

ندارد

ندارد

دارد

دارد

دارد

دارد

ندارد

 

کیندلینگ

 

ندارد

ندارد

دارد

دارد

دارد

دارد

ندارد

 

پتانسیل برانگیخته بینایی

 

ندارد

ندارد

دارد

دارد

ندارد

دارد

ندارد

 

دسته بندی اسپایک ها

 

ندارد

ندارد

ندارد

ندارد

Offline

Offline/Online

ندارد

Animal electrophysiology system

 

Brain and Spinal cord / Invio and invitro

extracellular recording(LFP,Single unit, ECog)

intracellular and Patch Clamp recording 

EXG recording animal (EEG,EMG,ECG,EOG,T,GSR,BVP)

Amplifiers, Electrical & Mechanical Stimulatars, Data acquisition, Window discriminators,Spike Sorter, Digital Microdrive, spike sorter

 

  

 

Human electrophysiology

 

eWave2,8: Biofeedback & Neurofeedback System

 

eWave 128, 64, 32 & 16Wireless ERP, QEEG and EXG(EEG,EOG,EMG,ECG) 

 

eWave4S : EP-EMG/NCV recording

 

eProbe: an effective software for neurofeedback data Recording and analysis!

 

eProbe All you need to analysis neuro-electrophysiology signals

All

 Field potential signal analysis

 

Import data from previous version (NeuroTrace)
Display signal on high performance offline scope
Ability to optimize scope scales, both vertical and horizontal
Signal visualization in single and multi-trial mode
Signal inverting
Trial trimming (Disable bad trial) 
Hyper polarization, EPSP, PS, VP. 
One and multi trial Analysis 
Four LFP analysis mode (Standard, EPSP, Volley Potential (VP) + EPSP, PS mode)
Automatic measurement of defined variables (max, min, slope of the all analysis  line, 90%-10% of the line slope, area under the curve, start time, delay and response end) 
Saving data analysis as a binary or excel file/ image/ analysis template
 
Potentalize EPSP

 

Single-unit signals (spike) analysis

 

PSTH hand             

               PSTH Analysis

 

 

                - Show sorted action potential in window discriminator

  

                - Show 8 channel  PSTH

                - Audio monitoring of raw signal and spikes  

                - Measurement of delayed and frequency response, max, min, average,

                  standard deviation and neuronal responses

                - Analysis for spinal cord neurons

                - Saving data analysis as a binary or excel file/ image/ analysis template

                

EEG signal analysis


 

 

Spike count

 

Calculating of spike number
Saving data analysis as binary or excel file/ image/ analysis template

SpikeCount

 

 break 

 

FFT         

Frequency analysis

 

Caclculate power and phase frequency range 0-100 HZ, between two custome time
Drowing power and phase frequency graph
Saving data analysis as binary or excel file/ image

break

Statistical analysis

 

PSTH statis

eProbe a potent software for neuro-electrophysiology data analysis!

 

 

PSTH hand 

 

 

Potent software for electrophysiological data analysis.

Data extraction from EEG, field potential and single-unit signals (PSTH analysis and offline sorting) and statistical analysis of acquired data.

PSTH analysis and real time demonstration of recorded signals in single-unit data analysis mode with offline sorting and analysis capabilities.

Making data banks from results in excel or word files format.

Online demonstration of raw signal.

Offline PSTH analysis output includes average firing rate of neuron, standard deviation of firing, latency time of response, minimum and                           maximum response and spike count of different types of nerve fibers.

Special modes for analyzing Uni-trial and multi-trial experiments.

Analysis Field potential, volley potential, EPSP and PS signals in single-pulse or paired-pulse recording mode.

EPSP analysis including baseline resetting, measuring slope, amplitude, area under curve, latency time and minimum and maximum response.

EEG analysis including spike count, average of spikes amplitude, phase and power spectrum.

Graphical output for using in scientific manuscripts.

User friendly installation and application. 

Complete manual for installation, application and analysis.

 

break

Some publications dealing with eProbe

Effects of apomorphine and β-carbolines on firing rate of neurons in the ventral pallidum in the rats; 
Behavioural Brain Research, Volume 227, Issue 1, 1 February 2012, Pages 109-115
Formalin-Induced Differential Activation of Nucleus Cuneiformis Neurons in the Rat: An Electrophysiological Study; The Journal of Pain, Volume 11, Issue 1, January 2010, Pages 32-43
Single whisker experience started on postnatal days 0, 5 or 8 changes temporal characteristics of response integration in layers IV and V of rat barrel cortex neurons;
Brain Research Bulletin, Volume 74, Issues 1–3, 14 September 2007, Pages 29-36
Dorsal raphe nucleus stimulation modulates the response of layers IV and V barrel cortical neurons in rat; Brain Research Bulletin, Volume 68, Issue 6, 15 February 2006, Pages 430-435
Electrical stimulation of locus coeruleus strengthens the surround inhibition in layer V barrel cortex in rat; Neuroscience Letters, Volume 401, Issue 3, 3 July 2006, Pages 280-284
بالا