eLab is a General purpose data acquisition system for recording action potential (Spikes), Field Potential, EEG, and signal modulation by external digital events.
Applicable on variety of subject
Rodents
Primates
All in one
microelectrode amplifier
stimulator isolator
pulse generator
digital and analog scope
amplitude window discriminator
delay line
data acquisition
four channels of microiontophoresis curent genrator
powerful online spike sorting for spike clustering.
Artistic design for scientific aim
Microelectrode amplifier is optimized for:
low noise
high dynamic range
low power dissipation
record EEG, LFP and single-unit signals simultaneously from the stream of one electrode by one ADC channel with 24 bit precision.
Design the best possible stimulus protocol by a digital pulse generator (single protocol or multi protocol)
two channel of DAC (digital to analog converters) and two channel of mechanical stimulator.
Hardware and software made for each other
You've never seen any electrophysiology setup like eLab
Because there's never been any thing like that
Data acquisition | ||
Processor | 32 bit ,168MHz | |
FIFO Memory | 64KB | |
Data transfer | USB2/ 480Mb | |
Analog to digital converter | Channel numners | 2/4/8/16 Channels |
ADC resolution | 24bit | |
Linearity error | ±7.6ppm (maximum) | |
Sample rate | 50Ks/s per channel | |
Analog input range | ±2.5v | |
Interface | Serial | |
Isolation type | Optical | |
Isolation voltage | 2500V | |
Isolation resistance | 10 12Ω | |
Electrical stimulator | Mode | Constant current, Unipolar, Isolated |
Number of channels | 1 Channels | |
Current range | 0 to 4mA or 0 to 20mA (optional) | |
Current resolution | 1µA or 5µA (optional) | |
Output waveform | DC or current pulse | |
current control | Yes, software controll by 12 bit DAC | |
Current amplitude error | 3LSB (maximum) | |
Polarity inversion | Yes, software controll by Relay | |
Output switch | Yes, software controll by Relay | |
Output voltage compliance | 150V | |
Current rise time and delay | 5μs, typical (1KΩ load) | |
Current fall time and delay | 5μs, typical (1KΩ load) | |
Isolation type | Optical | |
Isolation voltage | 2500V | |
Isolation resistance | 10 12Ω | |
Microelectrode Amplifier | Amplifier Type | Differential, Isolated, Extracellular |
Number of channels | 2/4/8/16 Channels | |
Gain | 30 | |
Input voltage range | ±2.5V | |
Maximum analog input voltage | ±2.5V | |
Input impedance | 10 12Ω, common mode and differential | |
Input leakage current | 60pA (typical) | |
Input capacitance | 8pF | |
Common mode rejection ratio | 75dB @ 50/60Hz | |
Isolation type | Optical | |
Isolation voltage | 2500V | |
Isolation resistance | 10 12Ω | |
Low cut filter | 0.1, 1, 10, 30, 50, 100, 300Hz | |
High cut filter | 30, 50,100, 300, 1000,3000,5000, 10000Hz | |
![]() | ||
Pulse generator | Experiment protocols | Single trial, Multi trial , Single protocol, Multi-protocol |
Stimulation Timing pattern | 4 | |
Pattern parameters | Delay, Pulse duration, Pulse cycle, Pulse Numbers, Trial period, Trial Number | |
Timing pattern resolution | 10us | |
Mixers | 2ch Internal stimulator, 2ch Mechanical stimulator , 2ch Digital outs | |
Mixer Inputs | Pattern1, Pattern2, Pattern3, Pattern4, Digital Input1, Digital Input2 | |
![]() |
Requirements | PC specification | CPU : i5 |
Operating System | Windows 7- 8.1- 10 |
eProbe All you need to analysis neuro-electrophysiology signals |
![]() |
| ![]() |
Single-unit signals (spike) analysis
| |
![]() | PSTH Analysis
- Show sorted action potential in window discriminator
- Show 8 channel PSTH - Audio monitoring of raw signal and spikes - Measurement of delayed and frequency response, max, min, average, standard deviation and neuronal responses - Analysis for spinal cord neurons - Saving data analysis as a binary or excel file/ image/ analysis template |
Spike count
Calculating of spike number | Saving data analysis as binary or excel file/ image/ analysis template | | ![]() | ||
| |||||
![]() |
|
![]() |
eProbe a potent software for neuro-electrophysiology data analysis!
Potent software for electrophysiological data analysis.
Data extraction from EEG, field potential and single-unit signals (PSTH analysis and offline sorting) and statistical analysis of acquired data.
PSTH analysis and real time demonstration of recorded signals in single-unit data analysis mode with offline sorting and analysis capabilities.
Making data banks from results in excel or word files format.
Online demonstration of raw signal.
Offline PSTH analysis output includes average firing rate of neuron, standard deviation of firing, latency time of response, minimum and maximum response and spike count of different types of nerve fibers.
Special modes for analyzing Uni-trial and multi-trial experiments.
Analysis Field potential, volley potential, EPSP and PS signals in single-pulse or paired-pulse recording mode.
EPSP analysis including baseline resetting, measuring slope, amplitude, area under curve, latency time and minimum and maximum response.
EEG analysis including spike count, average of spikes amplitude, phase and power spectrum.
Graphical output for using in scientific manuscripts.
User friendly installation and application.
Complete manual for installation, application and analysis.
Some publications dealing with eProbe
Effects of apomorphine and β-carbolines on firing rate of neurons in the ventral pallidum in the rats; Behavioural Brain Research, Volume 227, Issue 1, 1 February 2012, Pages 109-115 |
Formalin-Induced Differential Activation of Nucleus Cuneiformis Neurons in the Rat: An Electrophysiological Study; The Journal of Pain, Volume 11, Issue 1, January 2010, Pages 32-43 |
Single whisker experience started on postnatal days 0, 5 or 8 changes temporal characteristics of response integration in layers IV and V of rat barrel cortex neurons; Brain Research Bulletin, Volume 74, Issues 1–3, 14 September 2007, Pages 29-36 |
Dorsal raphe nucleus stimulation modulates the response of layers IV and V barrel cortical neurons in rat; Brain Research Bulletin, Volume 68, Issue 6, 15 February 2006, Pages 430-435 |
Electrical stimulation of locus coeruleus strengthens the surround inhibition in layer V barrel cortex in rat; Neuroscience Letters, Volume 401, Issue 3, 3 July 2006, Pages 280-284 |
محصول
|
electromodule |
eLab2/4/8/16/32 |
eClamp |
تعداد کانال آمپلی فایر
|
1 |
8/16/32 |
1 |
نوع آمپلی فایر
|
تفاضلی/مستقیم |
تفاضلی/مستقیم |
مستقیم |
دقت مبدل آنالوگ به دیجیتال
|
24 bit
|
24 bit
|
24 bit |
نرخ نمونه برداری هرکانال
|
50ks/s
|
30-50ks/s |
100ks/s |
پردازش گر
|
FPGA |
32bit/168MHZ |
32bit/168 MHZ |
نوع اتصال
|
USB2 |
USB2 |
USB2 |
محرک جریان
|
دارد 4/20mA,150V)) |
دارد ( 4/20mA,150V) |
دارد ( 4/20mA,150v) |
بهره
|
20 |
50 |
1 |
ورودی دیجیتال
|
2 |
2 |
2 |
خروجی دیجیتال
|
2 |
2 |
2 |
ورودی آنالوگ
|
0 |
0 |
0 |
خروجی آنالوگ
|
0 |
0 |
0 |
ابعاد(طول/عرض/ارتفاع)mm |
366x116x350 |
120x28x60 |
120x28x60 |
مقاومت ورودی
|
1012 Ω |
1012 Ω |
1012 Ω |
کارکردباتری قابل شارژ
|
5V
adaptor–no Bat |
5V USB input –no Bat |
5V
USB input –no Bat |
پهنای باند فیلتر |
0.5Hz -3KHz |
0.5Hz
-10KHz |
DC
-10KHz |
کاربرددرثبت
الکتروانسفالوگرام/ الکتروکورتیکوگرام/ الکتروکاردیوگرافی/ الکترومیوگرافی الکترواکولوگرافی |
دارد |
دارد |
ندارد |
کاربرددرثبت پتانسیل وابسته به رخداد(ERP) |
ندارد |
دارد |
ندارد |
سنسور مقاومت
پوست،دما،فشارخون حجمی، EEG,EMG,ECG |
ندارد |
ندارد |
ندارد |
ثبت پتانسیل میدانی(LFP) |
دارد |
دارد |
ندارد
|
ثبت تک واحدی(SUR)
|
دارد |
دارد |
ندارد |
ثبت داخل سلولی Patch Clamp (Voltage
/Current |
ندارد |
ندارد |
دارد |
ثبت سرعت هدایت عصبی(NCV) |
دارد |
دارد |
ندارد |
کیندلینگ
|
دارد |
دارد |
ندارد |
پتانسیل برانگیخته بینایی
|
ندارد |
دارد |
ندارد |
دسته بندی اسپایک ها
|
Offline |
Offline/Online |
ندارد |
eLab is a General purpose data acquisition system for recording action potential (Spikes), Field Potential, EEG, and signal modulation by external digital events.
Applicable on variety of subject
Rodents
Primates
All in one
microelectrode amplifier
stimulator isolator
pulse generator
digital and analog scope
amplitude window discriminator
delay line
data acquisition
four channels of microiontophoresis curent genrator
powerful online spike sorting for spike clustering.
Artistic design for scientific aim
Microelectrode amplifier is optimized for:
low noise
high dynamic range
low power dissipation
record EEG, LFP and single-unit signals simultaneously from the stream of one electrode by one ADC channel with 24 bit precision.
Design the best possible stimulus protocol by a digital pulse generator (single protocol or multi protocol)
two channel of DAC (digital to analog converters) and two channel of mechanical stimulator.
Hardware and software made for each other
You've never seen any electrophysiology setup like eLab
Because there's never been any thing like that
Data acquisition | ||
Processor | 32 bit ,168MHz | |
FIFO Memory | 64KB | |
Data transfer | USB2/ 480Mb | |
Analog to digital converter | Channel numners | 2/4/8/16 Channels |
ADC resolution | 24bit | |
Linearity error | ±7.6ppm (maximum) | |
Sample rate | 50Ks/s per channel | |
Analog input range | ±2.5v | |
Interface | Serial | |
Isolation type | Optical | |
Isolation voltage | 2500V | |
Isolation resistance | 10 12Ω | |
Electrical stimulator | Mode | Constant current, Unipolar, Isolated |
Number of channels | 1 Channels | |
Current range | 0 to 4mA or 0 to 20mA (optional) | |
Current resolution | 1µA or 5µA (optional) | |
Output waveform | DC or current pulse | |
current control | Yes, software controll by 12 bit DAC | |
Current amplitude error | 3LSB (maximum) | |
Polarity inversion | Yes, software controll by Relay | |
Output switch | Yes, software controll by Relay | |
Output voltage compliance | 150V | |
Current rise time and delay | 5μs, typical (1KΩ load) | |
Current fall time and delay | 5μs, typical (1KΩ load) | |
Isolation type | Optical | |
Isolation voltage | 2500V | |
Isolation resistance | 10 12Ω | |
Microelectrode Amplifier | Amplifier Type | Differential, Isolated, Extracellular |
Number of channels | 2/4/8/16 Channels | |
Gain | 30 | |
Input voltage range | ±2.5V | |
Maximum analog input voltage | ±2.5V | |
Input impedance | 10 12Ω, common mode and differential | |
Input leakage current | 60pA (typical) | |
Input capacitance | 8pF | |
Common mode rejection ratio | 75dB @ 50/60Hz | |
Isolation type | Optical | |
Isolation voltage | 2500V | |
Isolation resistance | 10 12Ω | |
Low cut filter | 0.1, 1, 10, 30, 50, 100, 300Hz | |
High cut filter | 30, 50,100, 300, 1000,3000,5000, 10000Hz | |
![]() | ||
Pulse generator | Experiment protocols | Single trial, Multi trial , Single protocol, Multi-protocol |
Stimulation Timing pattern | 4 | |
Pattern parameters | Delay, Pulse duration, Pulse cycle, Pulse Numbers, Trial period, Trial Number | |
Timing pattern resolution | 10us | |
Mixers | 2ch Internal stimulator, 2ch Mechanical stimulator , 2ch Digital outs | |
Mixer Inputs | Pattern1, Pattern2, Pattern3, Pattern4, Digital Input1, Digital Input2 | |
![]() |
Requirements | PC specification | CPU : i5 |
Operating System | Windows 7- 8.1- 10 |
eProbe All you need to analysis neuro-electrophysiology signals |
![]() |
| ![]() |
Single-unit signals (spike) analysis
| |
![]() | PSTH Analysis
- Show sorted action potential in window discriminator
- Show 8 channel PSTH - Audio monitoring of raw signal and spikes - Measurement of delayed and frequency response, max, min, average, standard deviation and neuronal responses - Analysis for spinal cord neurons - Saving data analysis as a binary or excel file/ image/ analysis template |
Spike count
Calculating of spike number | Saving data analysis as binary or excel file/ image/ analysis template | | ![]() | ||
| |||||
![]() |
|
![]() |
eProbe a potent software for neuro-electrophysiology data analysis!
Potent software for electrophysiological data analysis.
Data extraction from EEG, field potential and single-unit signals (PSTH analysis and offline sorting) and statistical analysis of acquired data.
PSTH analysis and real time demonstration of recorded signals in single-unit data analysis mode with offline sorting and analysis capabilities.
Making data banks from results in excel or word files format.
Online demonstration of raw signal.
Offline PSTH analysis output includes average firing rate of neuron, standard deviation of firing, latency time of response, minimum and maximum response and spike count of different types of nerve fibers.
Special modes for analyzing Uni-trial and multi-trial experiments.
Analysis Field potential, volley potential, EPSP and PS signals in single-pulse or paired-pulse recording mode.
EPSP analysis including baseline resetting, measuring slope, amplitude, area under curve, latency time and minimum and maximum response.
EEG analysis including spike count, average of spikes amplitude, phase and power spectrum.
Graphical output for using in scientific manuscripts.
User friendly installation and application.
Complete manual for installation, application and analysis.
Some publications dealing with eProbe
Effects of apomorphine and β-carbolines on firing rate of neurons in the ventral pallidum in the rats; Behavioural Brain Research, Volume 227, Issue 1, 1 February 2012, Pages 109-115 |
Formalin-Induced Differential Activation of Nucleus Cuneiformis Neurons in the Rat: An Electrophysiological Study; The Journal of Pain, Volume 11, Issue 1, January 2010, Pages 32-43 |
Single whisker experience started on postnatal days 0, 5 or 8 changes temporal characteristics of response integration in layers IV and V of rat barrel cortex neurons; Brain Research Bulletin, Volume 74, Issues 1–3, 14 September 2007, Pages 29-36 |
Dorsal raphe nucleus stimulation modulates the response of layers IV and V barrel cortical neurons in rat; Brain Research Bulletin, Volume 68, Issue 6, 15 February 2006, Pages 430-435 |
Electrical stimulation of locus coeruleus strengthens the surround inhibition in layer V barrel cortex in rat; Neuroscience Letters, Volume 401, Issue 3, 3 July 2006, Pages 280-284 |
محصول
|
electromodule |
eLab2/4/8/16/32 |
eClamp |
تعداد کانال آمپلی فایر
|
1 |
8/16/32 |
1 |
نوع آمپلی فایر
|
تفاضلی/مستقیم |
تفاضلی/مستقیم |
مستقیم |
دقت مبدل آنالوگ به دیجیتال
|
24 bit
|
24 bit
|
24 bit |
نرخ نمونه برداری هرکانال
|
50ks/s
|
30-50ks/s |
100ks/s |
پردازش گر
|
FPGA |
32bit/168MHZ |
32bit/168 MHZ |
نوع اتصال
|
USB2 |
USB2 |
USB2 |
محرک جریان
|
دارد 4/20mA,150V)) |
دارد ( 4/20mA,150V) |
دارد ( 4/20mA,150v) |
بهره
|
20 |
50 |
1 |
ورودی دیجیتال
|
2 |
2 |
2 |
خروجی دیجیتال
|
2 |
2 |
2 |
ورودی آنالوگ
|
0 |
0 |
0 |
خروجی آنالوگ
|
0 |
0 |
0 |
ابعاد(طول/عرض/ارتفاع)mm |
366x116x350 |
120x28x60 |
120x28x60 |
مقاومت ورودی
|
1012 Ω |
1012 Ω |
1012 Ω |
کارکردباتری قابل شارژ
|
5V
adaptor–no Bat |
5V USB input –no Bat |
5V
USB input –no Bat |
پهنای باند فیلتر |
0.5Hz -3KHz |
0.5Hz
-10KHz |
DC
-10KHz |
کاربرددرثبت
الکتروانسفالوگرام/ الکتروکورتیکوگرام/ الکتروکاردیوگرافی/ الکترومیوگرافی الکترواکولوگرافی |
دارد |
دارد |
ندارد |
کاربرددرثبت پتانسیل وابسته به رخداد(ERP) |
ندارد |
دارد |
ندارد |
سنسور مقاومت
پوست،دما،فشارخون حجمی، EEG,EMG,ECG |
ندارد |
ندارد |
ندارد |
ثبت پتانسیل میدانی(LFP) |
دارد |
دارد |
ندارد
|
ثبت تک واحدی(SUR)
|
دارد |
دارد |
ندارد |
ثبت داخل سلولی Patch Clamp (Voltage
/Current |
ندارد |
ندارد |
دارد |
ثبت سرعت هدایت عصبی(NCV) |
دارد |
دارد |
ندارد |
کیندلینگ
|
دارد |
دارد |
ندارد |
پتانسیل برانگیخته بینایی
|
ندارد |
دارد |
ندارد |
دسته بندی اسپایک ها
|
Offline |
Offline/Online |
ندارد |